HIWIN MGW15C precision linear guide is widely used in precision medical equipment due to their high precision, high rigidity, lightweight design, and strong corrosion resistance. They are suitable for the linear motion requirements of surgical robots, precision testing instruments, medical imaging equipment, and automated diagnostic and treatment equipment.
What are the advantages of MGW15C precision linear guide in medical equipment?
High resistance to external torque: The widened track design allows a single axis to withstand extremely high bending moments, reducing equipment size.
Highly stable operation: The Gothic four-point contact design ensures almost no vibration during movement, avoiding interference with precision medical imaging.
Extreme cleanliness: Made of stainless steel (optional), it is resistant to corrosion from disinfectants and saline solutions, and generates extremely low dust.
High space utilization: The ultra-thin combined height (16mm) perfectly matches the trend of miniaturization and portability in medical instruments.

HIWIN MGW15C miniature wide-width linear guides are widely used in:
Automation equipment
Precision instruments
Semiconductor equipment
Optical inspection platforms
Medical equipment
Miniature mechanical structures
3D printing and miniature CNC modules
| HIWIN MGW Linear Guide Model | |
| MGW2C | MGW3C |
| MGW3H | MGW7C |
| MGW7H | MGW9C |
| MGW9H | MGW12C |
| MGW12H | MGW14C |
| MGW14H | MGW15C |
| MGW15H | |

Model No |
Dimensions of Assembly (mm) |
Dimensions of Block(mm) | Dimensions of Rail (mm) | Mounting Bolt for Rail |
Basic Dynamic Load Rating |
Basic Static Load Rating |
Static Rated Moment |
Weight | |||||||||||||||||||||
| Ma N-m |
Mp N-m |
My N-m |
Block kg |
Rail kg/m |
|||||||||||||||||||||||||
| H | H₁ | N | W | B | B₁ | C | L₁ | L | G | G. | Mxl | H₂ | Wg | W₈ | Hg | D | h | d | P | E | (mm) | C(kN) | C₀ (kN) | ||||||
| MGW12C | 14 | 3.4 | 8 | 40 | 28 | 6 | 15 28 |
31.3 | 46.1 60.4 |
– | 1.2 | M3x3.6 | 2.8 | 24 | – | 8.5 | 8 | 4.5 | 4.5 | 40 | 15 | M4x8 | 3.92 | 5.59 | 70.34 | 27.8 | 27.8 | 0.071 | 1.49 |
| MGW12H | 45.6 | 5.1 | 8.24 | 102.7 | 57.37 | 57.37 | 0.103 | ||||||||||||||||||||||
| MGW14C | 15 | 3.5 | 10 | 50 | 35 | 7.5 | 18 35 |
34.8 | 49.4 67.6 |
4.7 | M3 | M4x4.5 | 3.2 | 30 | 一 | 9 | 8 | 4.5 | 4.5 | 40 | 15 | M4 | 5.9 | 8.44 | 116.96 | 48.91 | 48.91 | 0.11 | 1.98 |
| MGW14H | 53 | 7.7 | 12.33 | 170.94 | 102.12 | 102.12 | 0.162 | ||||||||||||||||||||||
| MGW15C | 16 | 3.4 | 9 | 60 | 45 | 7.5 | 20 35 |
38 57 |
54.8 73.8 |
5.2 | M3 | M4x4.2 | 3.2 | 42 | 23 | 9.5 | 8 | 4.5 | 4.5 | 40 | 15 | M4x10 | 6.77 | 9.22 | 199.34 | 56.66 | 56.66 | 0.143 | 2.86 |
| MGW15H | 8.93 | 13.38 | 299.01 | 122.60 | 122.60 | 0.215 | |||||||||||||||||||||||
| Note:1.1 kgf=9.81N | |||||||||||||||||||||||||||||
| 2.MG2 and MG3 blocks should not be removed from the rail.If removing the blocks is necessary,the blocks shoudbe kept on the block inserts. | |||||||||||||||||||||||||||||