Ball screw is prone to temperature rise during high-speed operation. Temperature rise can affect positioning accuracy, operational stability, and service life. Common cooling methods include forced cooling, optimized lubrication, improved structural design, and thermal compensation.

I. Core Causes of Rapid Temperature Rise in High-Speed ​​Ball Screws
  • Speed ​​far exceeding the screw’s allowable Dm-N value leads to rapid heat generation due to ball friction.
  • Excessive preload setting multiplies frictional resistance at high speeds.
  • Incompatible grease type, excessive viscosity, or overfilling.
  • Misalignment or misalignment during installation causes lateral friction at high speeds.
  • A fully enclosed protective cover prevents heat dissipation due to poor ventilation.
  • Frequent sudden starts and stops, and high-speed reversals exacerbate heat generation due to impact loads.

Note: The DN value is commonly used to measure the high-speed performance of ball screws: DN value = screw diameter × speed.

A higher DN value places higher demands on heat dissipation, lubrication, and structural design.

II. The following methods can be used to reduce the temperature rise during high-speed operation of ball screws:
1. Forced Cooling Technology (Most Direct and Effective)

(1) Internal Cooling of Hollow Ball Screws (Hollow Technology)

Ball screws with a hollow structure are circulated with cooling oil or liquid to directly remove internal heat.

(2) External Cooling System

An external cooling system is installed on the ball screw, using methods such as cold air, cold mist, or spray cooling to lower the surface temperature.

Ball screw temperature rise
2. Optimized Lubrication Strategy

(1) Selection of High-Speed ​​Special Lubricants

Using special greases or synthetic lubricants that are resistant to high temperatures, extreme pressures, and have a low coefficient of friction can effectively reduce frictional heat generation.

(2) Optimized Lubrication Method

During high-speed operation, the amount of lubricant used should be controlled to avoid excessive grease causing stirring heat.

3. Optimize Structural Design and Operating Parameters

(1) Use Hollow Screw Structure

Hollow screws not only facilitate internal cooling but also reduce rotational inertia, thus reducing the heat load during high-speed operation.

(2) Optimize Ball Circulation and Contact Structure

Optimizing the ball circulation method, contact angle, and effective ball configuration can reduce rolling friction loss, thereby reducing heat generation.

(3) Reduce Friction Torque

Optimizing the internal structure of the screw pair can effectively reduce dynamic friction torque, thereby reducing heat generation during high-speed operation.

(4) Reasonably Control DN Value

Limit the maximum speed to avoid exceeding the allowable DN limit specified in the sample.

4. Thermal Compensation and Maintenance

(1) Pre-tensioning Design

Applying pre-tension to the ball screw can improve stiffness and compensate for thermal expansion, reducing thermal deformation caused by temperature rise.

(2) Reasonable Preload

Set the preload reasonably according to the operating speed. Excessive preload will increase frictional heat generation.

(3) Environmental thermal insulation

Properly insulate the lead screw from high-temperature components (such as motors) to prevent external heat conduction.

Ball screw temperature rise

III. Daily Precautions for High-Speed ​​Ball Screw Operation (Avoiding Overheating)

Avoid prolonged operation at speeds exceeding the rated speed.

Under heavy load conditions, simultaneous high-speed reciprocating motion is not recommended.

In high-speed applications, never mix with ordinary low-speed grease.

Complete sealing of the lead screw is not recommended to prevent heat buildup and poor heat dissipation.

Preload is not always better the higher it is; it should be appropriately controlled during high-speed operation.

If your equipment experiences severe ball screw overheating, positioning drift, or high-speed noise, it is recommended to promptly check the lubrication, installation, and preload parameters. If necessary, upgrade to a high-speed dedicated structure.